PTD 901 [WES DOS]
Throughfeed dishwasher With integrated dispenser and integrated water softener.
- Always the right programme - item-specific solutionsSpecific programme for items to be washed
Regardless of the items and how dirty they are, there is an effective programme for all requirements. - Optimum suds filtering- first-class filter systemHighly effective filter system
Outstanding dishwashing results and reliability are largely due to the highly effective filter system. - Simple and flexible operation – full-touch displayFull-touch display
All the main information is accessible quickly and easily via the convenient full-touch display. - Optimum work flow - push-through basket systemOptimum work flow thanks to push-through system
Basket loading, washing and emptying can be designed as a continuous process.












EAN 4002516485407 / Article number 61090104D / Material number 11917920
Construction type | Passthrough dishwasher Optimum work flow thanks to push-through system Basket loading, washing and emptying can be designed as a continuous process. |
---|---|
Range | Professional |
Model | Performance |
Wash system | Tank passthrough Tank wash system for optimum work flows An outstanding advantage of the tank wash system is the fact that the dishwasher is permanently ready for use as soon as it has reached its operating temperature. This is facilitated by the permanent supply of rinse water at a temperature of 65 °C. The result is extremely short cycles with outstanding cleaning results. |
Number of levels | 1 |
Front | Stainless steel |
Tank volume in l | 35 |
Suitable for retirement and care homes | |
---|---|
Suitable for hospitals | |
Suitable for small restaurants/bars | |
Suitable for hospitality industry | |
Suitable for guesthouses | |
Suitable for canteens | |
Suitable for child care facilities | |
Suitable for universities and schools | |
Suitable for fast food restaurants | |
Suitable for sports clubs |
Tested virucidal efficacy | Effective against viruses – scientifically proven According to certification issued by the InFluenc_H – Institute for Integrative Hygiene and Virology, cleaning with tank dishwashers in programmes 1, 2 and 3 using Miele’s ProCare Shine 10 A and 10 GC cleaning agents removes enveloped viruses including not only the coronavirus, for example, but also noroviruses and adenoviruses. |
---|---|
Circulation pump Qmax in l/min. | 300 |
Shortest programme duration in sec. Performance data The values quoted may vary depending on the on-site conditions (power connection/water intake temperature). | 50 |
Maximum final rinse temperature in °C | 90 |
Cleaning performance, plates/h Performance data The values quoted may vary depending on the on-site conditions (power connection/water intake temperature). | 1296 |
Cleaning performance, glasses/h Performance data The values quoted may vary depending on the on-site conditions (power connection/water intake temperature). | 3773 |
Cleaning performance, baskets/h Performance data The values quoted may vary depending on the on-site conditions (power connection/water intake temperature). | 72 |
Service life in wash cycles Note Our machines undergo intensive testing under laboratory conditions. The actual number of wash cycles may vary depending on actual usage behaviour, maintenance and care of the machine. | 438000 |
Electrical connection | 3N AC 380-415V 50HZ |
---|---|
Heater rating in kW | 8.2 |
Tank heater rating in kW | 2.5 |
Boiler heater rating in kW | 10.8 |
Total connected load in kW | 9.1 |
Fuse rating in A | 16 |
Length of mains connection cable in m Note The length refers to the supply lead on the outside of the appliance. | 3.5 |
Electrical connection | 3N AC 380-415V 50HZ |
---|---|
Heater rating in kW | 10.8 |
Total connected load in kW | 13.2 |
Fuse rating in A | 25 |
Electrical connection | 3N AC 380-415V 50HZ |
---|---|
Heater rating in kW | 11.7 |
Total connected load in kW | 14.7 |
Fuse rating in A | 32 |
Cold or hot water [number] | 1 |
---|---|
Maximum temperature of inlet water in °C | 60 |
Required flow pressure in bar | 1-6 |
Drain pump [DN] | 19 |
Drain pump head height from floor level, max. in c | 65 |
Booster pump | |
Integrated water softener | |
Maximum water hardness in mmol/l Note With a water hardness level of 0.53 mmol/l and above, the installation of a pre-connected water softener is recommended if an integrated water softener is not already available. | 5.35 |
Water consumption per wash cycle in l | 2.2 |
Length of water inlet hose in cm | 150 |
Length of water drain hose in cm | 150 |
Maximum height adjustment in mm | 35 |
---|---|
External dimensions with closed hood, height Note The dimension refers to the appliance height without the feet extended. | 1535 |
External dimensions with opened hood, height Note The dimension refers to the appliance height without the feet extended. | 2010 |
External dimensions, net width in mm | 635 |
External dimensions, net depth in mm | 750 |
External dimensions, gross height in mm Note Including packaging | 1660 |
External dimensions, gross width in mm Note Including packaging | 770 |
External dimensions, gross depth in mm Note Including packaging | 880 |
Usable space in wash cabinet, height in mm | 440 |
Usable space in wash cabinet, width in mm | 540 |
Usable space in wash cabinet, depth of lower basket in mm | 500 |
Usable space in wash cabinet, depth in mm | 550 |
In-feed height above floor in mm | 850 |
Net weight [kg] | 137 |
Gross weight in kg Note Including packaging | 151 |
Maximum floor load in N/m² Maximum floor bearing capacity Maximum floor bearing capacity states the maximum weight (N) that can be placed on the supporting surface on which the machine is installed. This maximum load bearing capacity is the result of adding up the weight of the machine, the load and the water in it, as well as the dynamic forces that occur during operation. | 2026 |
Emissions – sound pressure at workplace Emissions - sound pressure at workplace The emission sound pressure level depends on the programme and is a value given to the noise created by the machine. Miele Professional appliances have very low noise levels. | 62 dB(A) re 20 µPa |
---|
Programme for light soiling | |
---|---|
Programme for normal soiling | |
Programme for heavy soiling | |
Additional programme options | |
Wash ware specific | |
Soak | |
Self-cleaning | |
Descaling | |
Basic cleaning |
Integrated dispensing pump/dispensing module for rinsing agent | |
---|---|
Integrated dispensing pump/dispensing module for liquid cleaning agent | |
Highly effective filter system | |
Pump protection filter | |
Spray arm monitor for all spray arms | |
Manual hood operation | |
Automatic programme start once hood is closed | |
Wash cabinet made from high-quality stai | |
Heat recovery from waste water | |
Temperature indicator for tank and boiler | |
Hygienic tank wash cabinet | |
Rotating spray system (top + bottom) | |
A wide range of accessories (optional) |
Suction lances for external media canisters [number] | 2 |
---|
CE | |
---|---|
Complies with Machinery Directive 2006/42/EC | |
Splash-proof IPX5 | |
EMC radio suppressed | |
DIN EN 17735 | |
DIN SPEC 10534 | |
WRAS | |
UKCA |
Additional accessories and consumables
Find additional accessories and consumables to go with this product

Find here the accessories that can be bought additionally for this product.

Find here the consumables that can be bought additionally for this product.
You can download these CAD data for free. You will receive a download link via e-mail.
3D data RVT
3D data FBX
3D data IFC
3D data RFA
3D data DWG
-
1.Depending on site conditions (temperature of incoming water / power connection) values given may vary.
-
2.A description of the relevant methodology for PTD 70x can be found
a href="https://www.miele.com/media/ex/com/Professional/Pruefberichte_Virussiegel/PTD70x_Viruswirksamkeit_Testkriterien_Virus_effectiveness_test_criteria_2021-11-25.pdf" here /a . | A description of the relevant methodology for PTD 901 can be found a href="https://www.miele.com/media/ex/com/Professional/Pruefberichte_Virussiegel/PTD901_Viruswirksamkeit_Testkriterien_virus_effectiveness_test_criteria_04.22.pdf" here /a .